PayPal Credit - Buy now spread the cost

Liebert GXT3-6000RT230 UPS (6000va/4800w)

  • For UPS advice email SOLUTIONS@EBUYER.COM
  • 6000 VA/ 4800W
  • Single-phase on-line UPS with multiple output options
  • Installs in rack or tower configuration

View full description

QuickFind: 282282

Mfr part code: GXT3-6000RT230K

{{#lists}}
  • {{ title }}
  • {{/lists}}

    Liebert GXT3-6000RT230 UPS (6000va/4800w) Product Description

    Liebert GXT3 5 kVA to 10 kVA uninterruptible power supply (UPS) systems provide true on-line protection in the smallest cabinets in their capacity range. These data center power systems offer internal batteries, unlimited extended external batteries, and internal bypass capability, resulting in continuous uptime for the connected equipment. Multiple data center power output configurations allow quick connection of protected loads.
    Designed for rack-mount or tower modes, the Liebert GXT3 uninterruptible power system is available in 5kVA and 6kVA, 4U models; and 8kVA and 10kVA, 6U models. All models are available with output of 120/208V. Please note that the internal batteries for the Liebert GXT3 5kVa to 10kVA UPS must be ordered separately, and will ship separately. Depending upon the model you select, there may also be a separate POD required.

    Please note: networking components such as switches, routers, UPS and wireless devices require that speeds & standards be consistent throughout the network to gain optimum performance. To avoid compatibility clashes or for advice, please contact us on solutions@ebuyer.com.

    Liebert GXT3-6000RT230 UPS (6000va/4800w) Product Reviews

    Technical Specifications

    General

    Width 57 cm
    Depth 43 cm
    Height 22 cm
    Weight 60 kg
    Device Type UPS - Power Factor Correction (PFC) - external
    Height (Rack Units) 5U
    Rack Size 19"

    Power Device

    Surge Suppression Yes
    Input Connector(s) Hardwire
    Output Voltage AC 230 V 50/60 Hz
    Power Output Connectors Details 4 x power IEC 60320 C13 ¦ 2 x power IEC 60320 C19 ¦ 1 x hardwire
    UPS Technology On-line
    Input Voltage AC 220/230/240 V
    Input Voltage Range AC 176 - 280 V
    Frequency Provided 50/60 Hz
    Frequency Required 40 - 70 Hz
    Input Connectors Hardwire
    Power Capacity 4.8 kW / 6000 VA
    Output Waveform Sinewave
    Circuit Protection Circuit breaker

    Battery

    Recharge Time 3 hours
    Quantity 20
    Technology Lead Acid
    Voltage Provided 12 V
    Capacity 9 Ah
    Run Time (Up To) 6 min at full load ¦ 17 min at half load

    Expansion / Connectivity

    Interfaces 1 x management (USB) - 4 pin USB Type B ¦ 1 x EPO (emergency power off)
    Expansion Slot(s) 1 (total) / 1 (free) x Liebert IntelliSlot
    Expansion Slots 1 (total) / 1 (free) x Liebert IntelliSlot

    Manufacturer Warranty

    Service & Support Limited warranty - 2 years
    Service & Support Details Limited warranty - 2 years

    Networking

    Remote Management Interface USB

    Miscellaneous

    Rack Mounting Kit Included
    Features Emergency power off, built-in maintenance bypass, internal bypass
    Compliant Standards EN 61000-4-4, EN 61000-4-2, EN 61000-4-3, IEC 62040-1-1, EN 61000-4-5, IEC 62040-2

    Software / System Requirements

    Software Included Liebert MultiLink, Liebert Nform

    Environmental Parameters

    Min Operating Temperature 0 °C
    Max Operating Temperature 40 °C
    Humidity Range Operating 0 - 95%
    Sound Emission 50 dBA

    Dimensions & Weight

    Width 57 cm
    Depth 43 cm
    Height 22 cm
    Weight 60 kg

    Dimensions & Weight (Shipping)

    Shipping Width 74.5 cm
    Shipping Depth 53 cm
    Shipping Height 51.6 cm
    Shipping Weight 71 kg

    Customer Questions

    Liebert GXT3-6000RT230 UPS (6000va/4800w) Ask an owner

    Liebert GXT3-6000RT230 UPS (6000va/4800w) Product Discussion

    Our comments box is a great way for you to view other people's feedback about products on Ebuyer.com, and add your own.

    • This tool is open to everyone.
    • You are responsible for the contents of your comments and any consequences that may arise as a result of them.
    • Comments that contain any of the following will be deleted: terms considered explicit and inappropriate; defamatory, obscene, unlawful, harmful, or offensive.